Skip to main content

Drone Not Syncing

Dealer-side checks when a customer drone shows offline or stale telemetry before escalating to OEM or GTEEX support.

Service technician
Support staff

Symptom

On Drones or Drone Detail, the unit shows Offline or telemetry timestamps lag by more than a minute while the customer insists the drone is powered on and flying (or recently landed).

Diagnosis

Work top to bottom — most cases are environmental, not RMA.

1. Expected offline

Between missions the aircraft is powered down. Offline is normal. Ask when the customer last powered on and whether the controller reported link.

2. Controller network path

Telemetry reaches the portal through the Controller. If the controller has no cellular or Wi-Fi, the portal stays Offline even when the RC link to the drone is fine.

  • Have the customer open a browser page on the controller.
  • Retry after moving within coverage or switching networks.

If the controller shows lost link to the drone, treat as field operations (range, interference, RTL) — not a dealer portal defect.

If RC link is healthy but portal is Offline, continue to step 4.

4. Dealer record checks

In Drone Detail:

  • Confirm the serial matches the physical label on the bench.
  • Check Block StatusBlocked units may suppress expected telemetry behavior until resolved in Settings.
  • Compare Firmware Version to OEM baseline; outdated firmware can stall sync after updates.

5. Portal session hygiene

Ask the customer to reload the customer portal and sign out/in. On your dealer view, refresh Monitoring or Drone Detail after two minutes — telemetry can backlog briefly after landing.

Fix

FindingAction
Powered offNo action; explain expected Offline
Controller offlineRestore network; retest
Wrong serial on ticketCorrect Drone on Support Ticket
BlockedClear block per policy or escalate to Distributor for factory hold
Firmware driftSchedule update per OEM bulletin before further repair
Still stale after aboveOpen internal ticket with serial, controller id, last-seen timestamp; escalate OEM if fleet-wide

Was this page helpful?

Edit this page on GitHub